Self-monitoring blood glucose system STANDARD GlucoNavii GDH
The STANDARD GlucoNavii GDH Blood Glucose Monitoring System (Glucometer) is designed to measure glucose levels both in capillary whole blood taken from a finger, palm, forearm or shoulder, and in venous blood. The STANDARD GlucoNavii GDH meter is used only with STANDARD GlucoNavii GDH test strips.
The device is intended for in vitro diagnostic use. This system is intended for independent use by patients who have been diagnosed with diabetes and for use in medical institutions to test the effectiveness of monitoring the condition of a patient with diabetes on an outpatient basis or in a hospital. This system is not intended for making a diagnosis - diabetes mellitus, as well as for self-testing of newborns. The STANDARD GlucoNavii GDH System can only be used by professionals to test newborns.
The STANDARD GlucoNavii GDH meter meets the accuracy criteria of international standards - EN ISO 13485: 2016, EN ISO 15197: 2015
Technical characteristics of the STANDARD GlucoNavii GDH meter:
Detection range 0.6-33.3 mmol / l (10-600 mg / dl).
Plasma Equivalent Calibration
A type of sample that uses capillary or venous whole blood
Blood glucose testing requires only 0.5 μL of blood
The meter shows the result 5 seconds after the drop of blood comes into contact with the test strip.
Electrochemical research method
The enzyme used in the test strips - Glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD)
Power supply 1 lithium battery 3V CR2032
Units of measurement mg / dl, mmol / l
Display type liquid crystal
Meter dimensions 48mm x 90mm x 15mm
Weight 50 g (including battery)
Automatic shutdown:
- 1 minute after measurement (use), without a test strip in the device
- 3 minutes after measurement (use), with a test strip in the device
Memory for 500 determinations with fixation of date, time and marking of the result
Additional functions of the meter:
Warning about the development of hypoglycemia at the level: 3.3; 3.9; 4.4 mmol / L
Marking results with "before" or "after" symbols
Automatic reminder to measure after eating
The ability to set up to 4 alarms
Calculation of the average for 7, 14, 30 days
- for all results
- for results marked "before" eating
- for results marked "after" eating
Meter operating temperature range 10 ° C - 45 ° C (50 ° F - 113 ° F)
Hematocrit level that does not affect the measurement result 0-70%
Test strip storage temperature 2 ° C - 32 ° C (36 ° F - 90 ° F)
Storing and shipping your meter -20 ° C to 50 ° C (-4 ° F to 122 ° F) at 10 to 93% relative humidity. -25 ° C to + 70 ° C (-13 ° F - 158 ° F) without battery.
The meter warranty is unlimited
Data transfer and storage Data transfer to a PC using a data cable, processing and storage of the results on your PC using software
Equipment**
Glucometer STANDARD GlucoNavii GDH - 1pc.
STANDARD GlucoNavii GDH test strips - 10 pcs.
Disposable sterile lancets - 10 pcs.
Lancet device with adjustable puncture depth - 1 pc.
Nozzle for blood collection from alternative sites - 1pc.
Battery CR2032 - 1pc.
Instructions for use - 1pc.
User's diary - 1pc.
Compact case for storage and transportation - 1pc.